Integrated panel preparationDD24SI and DD24DI modelsDishDrawerPréparation du panneau intégréModèles DD24SI et DD24DI DishDrawerACSU
SUCASafety and warningsCut HazardWARNING!Take care - panel edges are sharp.Failure to use caution could result in injury or cuts.Important! Read these instructions completely and carefully.Ensure the product is not plugged in.Installation of DishDrawer® panels requires basic mechanical and electrical skills.Installation must comply with your local building and electricity regulations.Failure to install the DishDrawer panels correctly could invalidate any warranty or liability claims.
ContentsDoublemodelsProductpreparationSinglemodelsProductpreparationPanel InstallationBadgecut-out,handleandpanelbracketSecuring the panel bracketsReconnecting the wires and fitting the panelsandacustomtoekick(double models only)Important! SAVE THESE INSTRUCTIONSThe models shown in this user guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please visit our local website listed on the back cover or contact your local Fisher & Paykel dealer.246781SUCA
SUCA2rPdocutperaparitDouble DishDrawer modelsC5A⁄1i6r ”g(8apmm)AonD.nim1⁄16”(2mm)Bthoeiegkhitckoflenapmin. ½ “ (12 mm)Installation diagrams for illustration purposes onlyThe following calculations assume the top of the upper panel is aligned with the top of the adjacent cabinetry. The nal panel/cabinetry alignment is achieved by adjusting the feet:width of ALL panelsMeasure A (the width between adjacent door/drawer fronts) and write it in the rst box below, then complete the equation. Adoor clearancepanel widthAdoor clearancewidth ALL panelseg 24¼” - 2 x 1⁄8” = 241⁄16”-2x=(616 mm)(2.5 mm)(611 mm)(min. 1⁄8” (2.5 mm))(min.237⁄16”(595 mm))height of upper panelstandard heightBuppheerigphatnelB door extensionheight upper paneleg 15 5⁄8” + 0 ”=15 5⁄8”15 5⁄8”+=(398 mm)(0 mm)(398 mm)(398 mm)(0 mm recommended)height of lower panelMeasure C (door/drawer height (or equivalent)) and write it in the rst box below, then complete the equation. CuppheerigphatnellowheerigphatnelCheight upper panelheight lower paneleg 30 ” - 15 5⁄8” - 5⁄16” = 14 1⁄16”--5⁄16” = (8 mm)(762 mm)(398 mm)(A8ir mgamp)(356 mm)(min.28¼”(717.5 mm) + B))Airgap(min.12¼”(311.5 mm))Note: The ‘door extension’ B allows for the top of the upper panel to be above the DishDrawer® where required.
rPdocutrpperataoin3Toe kick preparationheight of toe kick panelMeasure D (height from the top of adjacent cabinet door fronts to the oor) and write it in the rst box below, then complete the equation. height DBtoekhiecikgphtanelDBtoe kick paneleg 34 ¼ ” - 0” - 28 15⁄16” - ½ ” = 4 13⁄16”-- (7238515m⁄16m”)- (12½m”m) = (870mm)(0mm)(735mm)(12mm)(123mm)heicgahbtiandejtarcyentextdeonosironDidsihmDernasiwoenr®cleamriann.ce25⁄8”((7m0i.5n. mm))Toe kick options Theblackprefinishedtoekickpanelissupplied. This panel can also have a front panel of your choice attached to it using screws or an adhesive.Atoekickpanelofanymaterialwiththickness3⁄8 - ¾ ”(9 - 19 mm) can be screwed to the plastic toe kick panel bracket (supplied).(4312 7 m” m)(525 3m⁄16m” )(43R 2 ½m ”m)Integrated Panel materialmax.2 5⁄8” - 5”5⁄8 -13⁄16”(16 - 20 mm) panel thickness 2 5⁄8” (67mm)(67-127mm)Adequately sealed to withstand moisture (122OF/50OC @ 80% RH) Parts suppliedToe kicklenapscrews (5)sPcarneewlsp(a1n2e)lIntegrated door seal (2)(ISnatteignractherdormeectsaunpgpulileard)badge(2)bTroaeckkiectk(p1)anelPanel bracket (2)Prefinished Toe kick panel (1)SUCA
AsledomrewarDhsiDelgniSnoitaraperptcudorP4.nim1⁄16”(2mm)B3A⁄8ir”(g9ampm)3A⁄8ir”(g9ampm)Installation diagrams for illustration purposes onlyThe following calculations assume the top of the panel is aligned with the top of the adjacent cabinetry. width of the panelMeasure A (the width between adjacent door/drawer fronts) and write it in the rst box below, then complete the equation. Adoor clearancepanel widthAdoor clearancepanel widtheg 24¼” - 2 x 1⁄8” = 241⁄16”-2x=(616 mm)(2.5 mm)(611 mm)(min. 1⁄8” (2.5 mm))(min.237⁄16”(595 mm))height of the panelMeasure B (door/drawer height (or equivalent)) and write it in the rst box below, then complete the equation. Bpanel heightBpanel heighteg 16 ” - 3⁄8” = 15 5⁄8” - 3⁄8” (9 mm)Air gap =(407 mm)(9 mm)(398 mm)(min. 15 5⁄8” (398 mm))Air gapNote: when the top of the DishDrawer® has to be lower than the adjacent cabinetry, the panel can be increased in height.ACSU
Product preparation3⁄8”(9mm)3⁄8”(9mm)AirgapAir gapIntegrated Panel material5⁄8 -13⁄16”(16 - 20 mm) panel thickness Adequately sealed to withstand moisture (122OF/50OC @ 80% RH) Parts suppliedPanel panel screws (6)Integrated door seal (1)(ISnatteignractherdormeectsaunpgpulileard)badge(1)Panel bracket (1)5SUCA
SUCA6Badge cut-out, handle and panel bracketInstallation diagrams feature double models for illustration purposes only1Important!Ensure the product is not plugged in212143
3411Seucir2gntehp51⁄86”(16mmx6m) x6nalebarkctesHandles: Important!If mounting a handle: to avoid damage, ensure fastenings do not protrude beyond the back surface of the panel.2Double models only: Important!Break off the tab at the top of the Lower Panel Bracket37SUCA
SUCA8562aRnecdoancnuescttoinmgttoheekwicirke(sdoaunbdle mttoidnelgstohnley)panels 121Important!Ensure the rubber seal between the drawer and panels is kept in place2156⁄8” (1m6xm5m)x 5